2-Pin vs 3-Pin USB-C Chargers Grounding, Leakage Current, and Touch Current Explained
 
 
A customer connects a 100W USB-C charger to a metal-body laptop. Charging works normally, the USB PD negotiation is stable, and the adapter does not become unusually hot. Yet when the customer runs a finger across the laptop's aluminum housing, there is a faint tingling sensation. The charger is replaced with a three-prong adapter, and the sensation becomes less noticeable.
 
Does that mean the original two-pin charger was unsafe?
Not necessarily. This is one of those charging problems that cannot be understood by looking at output wattage or USB-C compatibility alone. The answer involves the charger's insulation system, AC input configuration, electromagnetic interference (EMI) suppression, leakage-current paths, and the way accessible metal parts interact with the surrounding environment.
 
For a USB-C charger manufacturer, these are design and safety-validation questions. They are particularly relevant to compact 65W, 100W, 140W, and higher-power GaN chargers used with metal-body laptops.
The important distinction is that a two-pin charger can be designed as a safe Class II product without protective earth, while a three-pin charger may use a protective earth connection as part of a Class I safety architecture. The number of plug contacts does not, by itself, establish whether a charger is safe or whether a user will experience touch current.
This guide explains the electrical differences, why a laptop may feel slightly tingly while charging, how leakage and touch current are measured, and what OEM buyers should verify before approving a charger design.
 
 
What Is the Difference Between a 2-Pin and 3-Pin USB-C Charger?
A two-pin USB-C charger normally connects to the AC supply through line and neutral, or the two corresponding supply conductors for its market. It does not have a protective earth connection.
A three-pin charger may provide an additional protective earth connection. However, the physical presence of a third pin is not enough to prove that it is connected to protective earth. Some plug systems include nonconductive earth-position pins, and certain products may use an earth connection for functional purposes rather than as a protective safeguard.
 
The correct distinction must therefore come from the product's electrical construction, insulation classification, and documentation.
In a conventional Class II charger, protection against electric shock is provided through double or reinforced insulation rather than a protective earth connection.
In a Class I charger, protective earthing forms part of the protection arrangement for relevant accessible conductive parts.
Both approaches can be appropriate when designed, manufactured, and evaluated according to the applicable safety requirements.
 
Quick Comparison: 2-Pin vs 3-Pin Chargers
Design characteristic Typical 2-pin Class II charger Typical 3-pin Class I charger
AC connection Supply conductors without PE Supply conductors plus PE
Primary shock protection Double or reinforced insulation Basic insulation with protective earthing where required
Protective earth required No Yes, for the Class I safety design
Output reference Often floating relative to earth Depends on the circuit and grounding arrangement
Leakage current May be present May also be present
Touch current Must meet applicable limits Must meet applicable limits
USB PD capability Depends on controller and power stage Depends on controller and power stage
These are typical configurations, not a rule that every charger with two or three physical pins follows the same architecture. For OEM buyers, the first question should be: What is the product's declared electrical safety class, and how is the protection system implemented?
 
Why a 2-Pin Charger Can Be Safe Without Grounding
A properly designed Class II charger does not depend on protective earth for its electric-shock protection. Instead, the power-conversion circuit must provide the required insulation and safeguards between the hazardous AC input and accessible parts, including the USB-C output interface.
This involves more than placing a transformer between the input and output. The complete insulation system includes the transformer construction, PCB spacing, insulation materials, component ratings, mechanical assembly, and the behavior of the product under relevant normal and fault conditions.
Basic, Supplementary, and Reinforced Insulation
Basic insulation provides a fundamental level of protection against electric shock.
Supplementary insulation provides an independent additional layer where required.
Reinforced insulation is a single insulation system providing a level of protection equivalent to double insulation under the applicable standard.
A Class II charger can use an appropriate combination of these insulation arrangements.
 
The actual construction must be evaluated under the relevant requirements of the applicable safety standard, commonly IEC 62368-1 for audio/video, information, and communication technology equipment. A charger factory should not claim that a charger is Class II merely because it has a plastic enclosure and two AC pins.
The transformer, insulation distances, PCB construction, and safety-critical components must support that classification.
 
Why the USB-C Output Is Not Connected Directly to AC Mains
An isolated USB-C wall charger uses an isolated power-conversion architecture to separate the AC input from the low-voltage output. The transformer and associated insulation system provide galvanic isolation between the relevant primary and secondary circuits.
However, galvanic isolation does not mean that absolutely no alternating current can flow through any path between the primary and secondary sides.
Parasitic capacitance and intentionally installed safety-rated capacitors can provide a small AC coupling path. This where the discussion of leakage current begins.
 
What Causes Leakage Current in USB-C Chargers?
Leakage current is current that flows through an unintended or intentionally controlled path outside the main functional power circuit. In an isolated charger, the relevant paths can include parasitic capacitance between transformer windings, capacitance between PCB structures, and safety-rated capacitors used for electromagnetic interference control.
 
At AC frequencies, a capacitor allows a displacement current to flow even though it does not provide a direct conductive connection like a wire. The magnitude depends on capacitance, applied voltage, frequency, and the complete circuit arrangement.
 
A simplified capacitive relationship is: I = 2 × π × f × C × V
Where:
• I = capacitive current in amperes
• f = AC frequency in hertz
• C = capacitance in farads
• V = RMS voltage across the capacitance
This relationship is useful for understanding the trend. It is not a substitute for measuring touch current through the prescribed network of a safety test instrument.
 
Why Higher AC Voltage Can Matter
For a fixed capacitance and frequency, capacitive current increases with applied voltage. That means a charger may produce a different leakage-current measurement at 230V AC than at 115V AC.
The operating frequency also matters.
 
A product intended for international markets should therefore be evaluated at the relevant input voltages and frequencies rather than tested only at one convenient laboratory supply condition.
For OEM charger projects targeting Europe, South Korea, the Middle East, and North America, this is an important part of defining the electrical test matrix.
 
What Is a Y Capacitor and Why Is It Used?
A Y capacitor is a safety-rated capacitor intended for applications where failure could create an electric-shock hazard, such as certain connections involving the primary and secondary sides of an isolated power supply.
 
In USB-C charger design, Y capacitors may be used to control common-mode electromagnetic interference.
A switching power supply generates high-frequency electrical noise. Without suitable filtering and layout, some of that noise can be conducted through the power connections or coupled into surrounding equipment.
A properly selected Y capacitor can provide a controlled high-frequency return path, improving EMI performance. However, the same capacitive coupling can contribute to AC leakage current.
This creates a real engineering tradeoff.
 
EMI Performance vs Leakage Current
Increasing the effective primary-to-secondary capacitance can improve certain common-mode noise characteristics, depending on the circuit. But it can also increase the capacitive current at the AC supply frequency.
Reducing capacitance may lower that current, but the design may then require other measures to maintain EMI performance.
 
These measures can include changes to transformer shielding, winding arrangement, PCB layout, common-mode filtering, and the overall power-conversion architecture. A charger engineer cannot simply remove the Y capacitor to eliminate a customer's tingling complaint without considering the electrical consequences.
The correct solution requires a review of the complete circuit and applicable safety requirements.
 
Why the Y Capacitor Must Be Safety Rated
A primary-to-secondary capacitor can form part of the safety-critical insulation arrangement. It must have the appropriate safety classification and ratings for its intended application.
The relevant component requirements are addressed by standards such as IEC 60384-14, while the complete product is evaluated under its applicable equipment safety standard. A general-purpose ceramic capacitor should not be substituted for a required safety-rated capacitor merely because the capacitance and voltage markings appear similar.
For a charger factory, Y-capacitor selection and supplier substitution must be controlled through the approved bill of materials.
 
Why Does a Laptop Feel Tingly When Charging?
The faint tingling sensation sometimes reported on a metal-body laptop is often associated with a small AC potential between the laptop's accessible metal surface and its surrounding environment.
With a floating-output two-pin adapter, capacitive coupling inside the power supply can establish a measurable AC voltage relative to earth.
When a person touches the metal surface, a small current may flow through the body and surrounding return path. Under some conditions, this can produce a tingling or vibrating sensation.
 
Lenovo and Huawei have both published support explanations addressing this behavior with certain two-pin AC adapters.
The sensation depends on several factors:
• Charger leakage-current characteristics and Input voltage and frequency
• Laptop enclosure and grounding arrangement and Contact area and skin condition
• Humidity and environmental conditions,  Footwear and flooring and Other connected peripherals
A person may notice the sensation in one environment and not another, even when using the same charger and laptop.
 
Does Tingling Mean the Charger Is Defective?
Not always. A mild sensation can occur with a correctly designed and compliant isolated power supply. However, the sensation alone cannot establish that the product is safe.
An abnormal charger, damaged cable, defective outlet, or insulation fault may also create an electrical hazard. A user experiencing a strong shock, painful sensation, sparks, unusual heating, burning smell, or other abnormal behavior should stop using the equipment and have it checked by a qualified professional.
From a manufacturing perspective, the correct response to a customer complaint is to investigate the actual electrical condition, not automatically classify every tingling report as harmless.
 
Why a 3-Pin Charger May Reduce the Sensation
In some charger and laptop configurations, a protective earth or functional earth reference can reduce the floating AC potential associated with the accessible metal surface. This can make the tingling sensation less noticeable. But a three-pin plug does not guarantee that the USB-C output is directly bonded to protective earth.
Some designs keep the secondary output isolated or use a controlled reference arrangement. The actual result depends on the internal circuit, the grounding architecture, the connected laptop, and the building's electrical installation.
A three-pin charger should not be described as universally free of touch current.
 
Leakage Current vs Touch Current: Why the Terms Matter
Leakage current and touch current are related, but they are not interchangeable.
Leakage current is a broad term covering current through paths outside the intended functional circuit.
Touch current is the current that can pass through a person or an equivalent measurement network when an accessible part is touched under defined conditions.
Protective conductor current is another distinct measurement involving current flowing in the protective earth conductor.
 
For a Class I product, protective conductor current may be present even when the accessible metal enclosure is properly earthed.
For a Class II product, the absence of protective earth does not mean the absence of capacitive current.
The safety evaluation must identify the relevant current path and apply the correct measurement method.
 
Why Measuring AC Voltage Alone Is Misleading
A high-impedance digital multimeter can display a substantial AC voltage between a floating USB-C output and earth. This does not automatically mean that the output can deliver dangerous current.
The meter draws very little current, so it may detect a voltage created through a high-impedance capacitive path. When a defined load or measurement network is connected, the voltage can change significantly.
 
For safety assessment, a simple voltage reading is not a substitute for a touch-current measurement. Likewise, the absence of a noticeable voltage reading does not prove that all relevant safety conditions have been satisfied.
Engineers must evaluate voltage, current, impedance, and the applicable test arrangement together.
 
IEC 62368-1 and IEC 60990: What Do They Require?
IEC 62368-1 is a hazard-based safety standard used for many audio/video, information, and communication technology products, including relevant external power supplies. It addresses electrical energy sources, safeguards, insulation, and other safety requirements.
 
IEC 60990 provides measurement methods for touch current and protective conductor current. The exact limits and procedures depend on the applicable edition, equipment classification, accessible parts, operating conditions, and fault assumptions.
It is therefore incorrect to state that every USB-C charger worldwide has one universal leakage-current limit.
 
Do Not Confuse Different Current Limits
Some technical documents and manufacturer support pages refer to values such as 250µA. Other documents define low-touch-current categories or provide different limits under specified conditions.
 
For example, IEC 63002:2016 describes low-touch-current external power supplies using particular criteria at 250V AC and 50Hz, including 65µA for certain supplies up to 30W and 100µA for certain supplies between 30W and 100W.
Those figures are specific to that classification and its stated test conditions. They are not universal pass/fail limits for every USB-C charger under IEC 62368-1. The charger manufacturer must identify which requirements apply to the product and the intended market.
 
Normal Conditions and Fault Conditions
Safety testing may require more than normal operation. Depending on the product and standard, engineers may need to evaluate specified abnormal or fault conditions.
These can include relevant supply conditions, insulation-related faults, protective-earth conditions, and other situations defined by the standard.
 
The correct test plan must follow the applicable edition and product construction. A charger factory should not invent a simplified test that appears to resemble a safety test and then claim formal compliance based on that resul
 
How a Charger Factory Measures Touch Current
A proper touch-current test requires the specified measuring network, calibrated equipment, and controlled electrical conditions. IEC 60990 defines methods used for relevant current measurements.
The test should be performed by qualified personnel using equipment suitable for mains-connected safety evaluation.
Step 1: Identify the Charger Classification
Confirm whether the charger is Class I or Class II. Review the approved safety construction, AC plug configuration, enclosure, insulation system, and intended grounding arrangement.
The test plan must match the actual design.
 
Step 2: Define the Measurement Points
For a USB-C charger, relevant accessible conductive paths may include the USB-C output interface and connected accessible parts, depending on the applicable procedure.
The test arrangement should identify exactly where the measurement network is connected. A bare charger, a charger with a cable, and a charger connected to a metal-body laptop may represent different measurement configurations.
These should not be mixed without documenting the test objective.
 
Step 3: Apply the Required AC Input Conditions
The test plan should include the relevant supply voltages and frequencies. Input conditions should be recorded, along with the operating state of the charger.
A multi-voltage product should not be approved based solely on one input condition unless that is sufficient under the applicable requirements.
 
Step 4: Use the Correct Measurement Network
A touch-current measurement is not simply a multimeter current reading. The measuring network represents defined electrical characteristics and provides the measurement method required by the relevant standard.
The equipment should be calibrated and used according to the applicable procedure.
 
Step 5: Evaluate Relevant Operating States
Depending on the product and requirements, the engineering team may examine no-load operation, defined output loading, and other specified operating states. USB PD operation should be recorded when it affects the electrical configuration being evaluated.
A 100W charger operating at 5V with little load is not necessarily representative of every operating condition.
 
Step 6: Record and Review the Results
A useful test report should include:
• Product model and hardware revision and Safety classification
• AC input voltage and frequency and Measurement points
• Measurement network and equipment and Operating condition
• Recorded current, Applicable acceptance criteria and Result and test date
The result should be evaluated against the correct requirement rather than an arbitrary factory threshold.
 
Why Hi-Pot Testing Does Not Replace Touch-Current Testing
Hi-pot, or dielectric withstand testing, is used to evaluate insulation performance under a specified elevated test voltage. It is an important part of electrical safety evaluation.
However, passing a dielectric withstand test does not automatically establish that the product meets touch-current requirements.
The two tests examine different characteristics.
 
A charger may have an insulation system that withstands the required dielectric test voltage while still exhibiting capacitive current during normal AC operation.
That current must be assessed using the applicable touch-current method. Conversely, a low measured touch current does not prove that the insulation system has adequate dielectric strength or spacing.
For a charger manufacturer, dielectric strength, insulation construction, and touch current are complementary parts of the safety-validation process.
 
How Charger Design Affects Leakage and Touch Current
Several engineering decisions influence the final result.
Transformer Construction
The transformer provides the isolation barrier in many USB-C charger architectures. Its winding arrangement, insulation system, shielding, and parasitic capacitance influence common-mode noise and primary-to-secondary coupling.
A transformer change can affect both EMI and touch-current performance even when the output voltage and power rating remain unchanged.
 
Y-Capacitor Value and Placement
The capacitance, safety classification, and circuit position of the Y capacitor influence the coupling path. A component substitution must therefore be reviewed for more than capacitance tolerance.
 
EMI Filter Architecture
Common-mode chokes, input filtering, switching behavior, and PCB layout all affect conducted emissions.
A change intended to improve EMI can alter leakage-current behavior.
The two characteristics should be evaluated together.
 
Switching Frequency and GaN Design
GaN technology can enable high-frequency switching and compact power-conversion structures.
However, faster switching edges and high-frequency noise require careful EMI management. A smaller charger is not automatically a lower-leakage charger.
The result depends on the complete electrical design, not simply whether the primary switch uses GaN or silicon technology.
 
PCB Insulation and Mechanical Assembly
Creepage, clearance, insulation materials, slots, component placement, and assembly consistency contribute to the product's electrical safety construction.
A PCB revision that changes the isolation region must be reviewed against the approved design and applicable requirements.
 
What Changes for 65W, 100W, 140W, and 240W Chargers?
Higher output power does not automatically mean proportionally higher touch current. The touch-current behavior is influenced primarily by the relevant coupling paths, supply conditions, circuit architecture, and safety design.
 
A 140W charger can have lower measured touch current than a 65W charger if its design produces a lower current through the applicable measurement network.
The power rating alone is not enough to predict the result. Nevertheless, higher-power chargers often have more demanding EMI and thermal requirements. Compact designs may use different switching topologies, transformer constructions, and filtering arrangements.
 
For a charger manufacturer, each platform should be evaluated independently. A 65W charger test report should not automatically be used to support a 140W or 240W design merely because the products share an enclosure style or brand.
 
Multi-Port Chargers Need Configuration Control
Multi-port GaN chargers introduce additional operating states. The internal power stage may change operating conditions as devices are connected or disconnected.
Engineers should identify which configurations are relevant to the safety evaluation and whether the test arrangement needs to include different loading states.
USB-C ports may share a common secondary ground, but the reference relationship between this secondary circuit and the protective earth (PE) is not explicitly defined. The actual circuit must be verified.
 
Common Mistakes When Comparing 2-Pin and 3-Pin Chargers
Assuming Two Pins Mean Poor Safety
A properly designed Class II charger can provide the required protection without protective earth. Its safety depends on the insulation system and applicable evaluation results.
 
Assuming Three Pins Eliminate Leakage Current
A Class I charger may still have leakage or protective conductor current. The protective earth arrangement changes the relevant current paths but does not make every capacitive current disappear.
 
Treating USB-C GND as Protective Earth
USB-C GND is the functional return path for the DC output.
Protective earth is a safety-related conductor in an AC installation. They are not automatically the same electrical node.
A manufacturer must not connect them together without a design-level safety and functional assessment.
 
Using a Multimeter Voltage Reading as a Safety Verdict
A floating output can show an AC voltage relative to earth when measured with a high-impedance instrument. That reading alone does not determine the available touch current or establish compliance.
 
Modifying a Charger to Add Grounding
Connecting a wire from a USB-C output, laptop enclosure, or charger case to a nearby earth contact is not an acceptable substitute for a properly designed grounding system. Such modifications can introduce new fault paths and compromise the approved safety construction.
Grounding arrangements should be implemented and verified by qualified engineers, not improvised by end users.
 
Ignoring the Actual AC Plug Construction
An EU two-pin plug, UK three-pin plug, and other regional plug configurations cannot be compared solely by counting visible pins. The actual electrical connections, plug standard, safety class, and intended market must be verified.
 
How OEM Buyers Should Specify Grounding and Touch-Current Requirements
For a private-label USB-C charger project, the electrical safety architecture should be defined before tooling and mass production. This is particularly important when a buyer plans to sell the same charger platform in multiple markets.
The OEM specification should establish:
1. Intended countries and plug types and Declared safety classification
2. Relevant product safety standards and editions and AC input voltage and frequency range
3. Insulation construction and safety-critical components and Grounding or functional-earth requirements
4. Applicable touch-current evaluation and Relevant operating and fault conditions
5. Approved component substitutions and Required test reports and production controls
 
A buyer should also clarify whether the product is intended primarily for smartphones, tablets, laptops, or a mixed device range. This matters because metal-body laptops may make touch-current characteristics more noticeable to end users, even when the charger is operating within its applicable requirements.
 
Ask for Actual Test Evidence
Terms such as "low leakage current" are not sufficiently precise. A valid test report must clearly specify the measurement method, test conditions, actual measured values, and the applicable limits.
If the purchaser’s requirements for user experience exceed the minimum safety standards, these should be explicitly stated. The engineering team can then evaluate the feasibility of these targets without compromising electromagnetic interference (EMI) performance, insulation properties, or other product characteristics.
 
Controlling Grounding and Insulation During Mass Production
A qualified prototype is only the starting point. The approved safety construction must be maintained when the charger enters volume production.
Changes to transformers, Y capacitors, PCB materials, insulation barriers, AC plug assemblies, or enclosure parts may affect the safety evaluation. The factory should control safety-critical components through the approved BOM and engineering-change process.
 
Incoming inspection should verify relevant component identities and specifications.
PCBA and assembly processes should maintain the approved insulation construction.
Production testing should follow the defined safety and functional inspection plan.
More detailed design-qualification and reliability tests should be performed according to the approved validation strategy.
 
Our guide to charger quality control during mass production explains how BOM control, incoming inspection, PCBA testing, and engineering-change management support consistent charger manufacturing.
For OEM buyers, the key question is whether the delivered charger matches the electrical and mechanical configuration that was originally evaluated.
 
How Grounding Relates to Charger Efficiency and Output Quality
Grounding, leakage current, output regulation, and conversion efficiency are distinct engineering characteristics.
A charger can achieve high efficiency even without a protective ground connection; a charger with a three-pin plug is not necessarily more efficient than one with a two-pin plug. Similarly, a charger with lower output ripple does not automatically have lower touch current.
The various relevant tests examine different aspects of a product.
Our article on charger efficiency and power-conversion losses discusses how manufacturers evaluate conversion efficiency. That performance measurement should not be confused with the charger's insulation or grounding classification. For OEM development, it is more useful to define each requirement independently and then evaluate the complete design.
 
Conclusion: Choose the Safety Architecture, Not Just the Plug
The difference between two-pin and three-pin USB-C chargers is not simply whether one has an extra metal contact. It is the underlying electrical safety architecture.
A properly designed Class II charger can operate safely without protective earth. A Class I charger uses protective earthing as part of its protection system. Both must satisfy the relevant safety requirements for their intended applications.
Leakage current can occur through capacitive coupling in isolated switching power supplies. In some configurations, that coupling can create a faint tingling sensation on a connected metal-body laptop. But a tingling sensation is not a substitute for an electrical safety test, and a three-pin plug does not automatically eliminate every touch-current path.
 
For charger manufacturers, the correct approach is to evaluate insulation construction, EMI filtering, Y-capacitor selection, touch-current behavior, and applicable safety requirements as one coordinated design. At ZONSAN, our charger OEM/ODM development work covers USB-C PD power platforms, electrical validation, product customization, and manufacturing control. For brands developing 65W–240W chargers for international markets, the intended plug configuration and electrical safety requirements should be confirmed before finalizing the product design.
A reliable charger should not only deliver the advertised wattage. Its electrical safety construction must also be appropriate for the market, equipment, and operating conditions it is designed to serve.
 
Frequently Asked Questions
Q1: Are 2-pin USB-C chargers safe?
Yes, a properly designed two-pin Class II USB-C charger can be safe without protective earth. Its electric-shock protection relies on the required insulation and safeguards rather than a grounding conductor. Safety must be verified against the applicable standards.
 
Q2: Why does my laptop feel tingly with a 2-pin charger?
Capacitive coupling inside an isolated power supply can create a small AC potential between a floating output and earth. When touching a metal-body laptop, a person may sometimes feel a faint tingling sensation. Abnormal or painful shocks require investigation.
 
Q3: Is a 3-pin charger better than a 2-pin charger?
Not automatically. The appropriate design depends on the equipment, electrical safety classification, intended market, and application. Both Class I and Class II chargers can be designed to meet applicable safety requirements.
 
Q4: Does a 3-pin charger have zero leakage current?
No. A three-pin charger may still have leakage current or protective conductor current. The grounding arrangement changes the current paths but does not eliminate every form of capacitive coupling.
 
Q5: What is the difference between leakage current and touch current?
Leakage current is a broad term for current flowing outside the intended functional circuit. Touch current is current that can flow through a person or specified measurement network when an accessible part is touched under defined conditions.
 
Q6: What does a Y capacitor do in a USB-C charger?
A safety-rated Y capacitor can provide a controlled high-frequency path for common-mode EMI suppression. It may also contribute to AC leakage current, so its selection must balance EMI performance and safety requirements.
 
Q7: Is USB-C ground the same as protective earth?
No. USB-C GND is the functional DC return path. Protective earth is a safety-related conductor in the AC electrical system. Whether they are connected depends on the specific product design.
 
Q8: How do charger manufacturers measure touch current?
Manufacturers use a defined measuring network and controlled test conditions, commonly following relevant IEC 60990 methods as required by the applicable product safety standard.
 
Q9: Can a charger pass hi-pot testing but fail touch-current testing?
Yes. Dielectric withstand and touch-current tests examine different characteristics. Passing one does not automatically demonstrate compliance with the other.
 
Q10: Does higher charger wattage mean higher leakage current?
Not necessarily. Touch-current behavior depends on the circuit's coupling paths, insulation arrangement, AC supply conditions, and measurement configuration rather than output wattage alone.
 
Q11: Should OEM buyers choose a grounded charger for metal-body laptops?
They should evaluate the intended laptop application, safety classification, grounding arrangement, touch-current requirements, and customer-experience targets. A grounded configuration may reduce noticeable tingling in some systems, but it is not a universal requirement.
 
Q12: What safety documents should a charger manufacturer provide?
Relevant documentation may include product safety certification or evaluation records, insulation construction information, applicable touch-current results, approved component information, and production quality-control records.